top of page

H2S ODOR CONTROL

An effective solution to eliminate H2S and a variety of associated gases. Designed for superior quality, low maintenance, and long term effectiveness in residential or municipal applications.
25050-450 with media.jpg

MEDIA

The heart of all of our odor control systems are canisters filled with Wager's highly effective media. Each blue canister holds a capacity of 50lb or 23kg.

 

All of our 2050 and 3000 series are all designed to include the same size media canisters. This makes it easier for the customer to order replacement canisters with media even if they have several different models in their network. 

When the media needs replacement, handles incorporated in the canister make it simple to swap out for a new canister provided by Wager. 

SIZING

Each of our 2050 series works exactly the same at eliminating H2S odors. They all feature air admittance valves, mist eliminator pad(s) and media canister(s). The number after 2050 represents how much media the system holds. For example 2050-450 holds 450lb. (204kg) of media in 9 canisters.

 

Selecting the right size system is dependent upon the parts per million (PPM) of H2S gas and the velocity of airflow entering the system. With a low concentration of H2S and airflow the model 2050-50   We try to size each system to get at least one year of service before the media canisters need to be replaced. 

LOW

PPM & AIRFLOW

HIGH

WHAT IS BEING VENTED?

Some situations where Wager Odor Control Systems can be found beneficial but also pose questions when determining what system is best. 

LIFT STATIONS

Q: What is the size of the main entering the station? 

A: Inside the pipe the sewer is forcing air out ahead of it. The volume of air is determined in part by the size of the pipe dumping into the station. The larger the pipe, the more airflow and splashing inside the wet well will occur.  

Q: How many pumps are inside the lift station. How many gallons per minute can they handle?

A:  Typically lift stations are equipped with duel pumps. These pumps are activated when the level of liquid reaches a certain level inside the wet well. These pumps then force the fluid out though the force main. Each pump will be rated to handle a specific amount of gallons per minute located in the pumps specifications. 

CFM

With this basic information we can help you determine the CFM (cubic feet per minute) and what Wager Odor Control System would be the correct model for each lift station. 

PPM

There are a couple of factors to consider when determining the PPM of H2S at a location 

  1. Older sewer line = Lower PPM

  2. Newer sewer line= Higher PPM

A H2S gas logger is an excellent tool to get an exact reading. Wager suggest getting these reading at peak times of the day. 7am & 7pm.

If you do not have a H2S gas logger, a good estimate is 100 PPM. 

Q: Is there use of Bioxide?

A: Bioxide will dramatically cut the PPM at the station but is a very expensive process. Wager's Odor Control Systems will act as a polisher in order to reduce the quantity of Bioxide needed if at all. I

If you know the CFM and the PPM for a location you can enter this information into our sizing estimator calculator. You can even compare our different systems against one another to see a good estimate of how many months can be achieved before media change outs. 

LIFT STATION RECOMNEDATIONS

In order for to Wager's Odor Control Systems to be highly effective. There are other scenarios that will need to be addressed. H2S gas will find the path of least resistance. Any area where the gas can escape, it will. Check the security of all fittings and make sure the hatch has a tight seal. We recommend a industrial rubber mat to lay over the hatch door when not in use .

 

Other areas to check near by for odors would be:

  • Air realease valves near the lift station.

  • vented manholes near the lift station. 

AIR RELEASE VALVES

Q: What is the size of the Main?

A: The larger the size of the pipe , the likelihood of higher concentrations of H2S (PPM). 

Q: What is the size of the Air Release Valve?

A: The larger the ARV, the more CFM of air it has to handle. 

Q: Where is the ARV located?

A: Generally there will be higher PPM and CFM at the beginning of the line. 

Q: Are all of the ARV's functioning properly and active on the line?

A: In situations where air release valves are inoperable deliberately shut down will effect the airflow further down the line. Venting is key to the efficiency of the system.

GRAVITY LINES

Q: What is the size of the gravity sewer line?

A: The larger the size of the pipe , the likelihood of higher concentrations of H2S (PPM). 

Q: Are there vent stacks or just manholes along the line? if there is vent stacks, what size?

A: 

Q: Is the manhole a street application? 

A: Wager offers a manhole scrubber that holds the same size media canister as our 2050 series. 

3000 with mist cutaway.jpg

WAGER 3000 MANHOLE SCRUBBER

perfect for street applications or where the forced main is dumping into the gravity line. 

For very low concentrations of H2S gas (5-15 CFM) on gravity lines or even roof vents we recommend our residential odor control valves for small applications. 

1200thumb.jpg

1200

Roof Vent Odor Control Valve

5lb Media

1 Canister

0 Mist Eliminator Pad

0 Air Admittance Valve

Est. 1-7 CFM

Not to be used with ARV"s

1800thumb.jpg

1800 

Odor Control Valve

12 lb Media

1 Canister

0 Mist Eliminator Pad

0 Air Admittance Valve

Est. 5-15 CFM

Not to be used with ARV"s

1850thumb.jpg

1850

Odor Control Valve with Float for water protection. 

12 lb Media

1 Canister

0 Mist Eliminator Pad

0 Air Admittance Valve

Est, 5-15 CFM

Not to be used with ARV's

Wager 2050 series are all designed to handled higher concentrations of H2S gas. They all include media canisters and Mist Eliminator Pads and Air Admittance Valves.

ODOR CONTROL SYSTEMS

2050-50.jpg

2050-50

ODOR CONTROL SYSTEM

Vertical Access Flange

50 lb Media

1 Canister

1 Mist Eliminator Pad

2 Air Admittance Valves

Est. 60-70 CFM

2050-100-sa.jpg

2050-100-SA

ODOR CONTROL SYSTEM

Side Access Flange

100 lb Media

2 Canisters

1 Mist Eliminator Pad

2 Air Admittance Valves

Est. 120-150 CFM

2050-450-thumb.jpg

2050-450

ODOR CONTROL SYSTEM

Side Access Flange

450 lb Media

9 Canisters

2 Mist Eliminator Pads

8 Air Admittance Valves

Est. 650-700 CFM

2050-1350thumb.jpg

2050-1350

ODOR CONTROL SYSTEM

Side Access Flange

1350 lb Media

27 Canisters

8 Mist Eliminator Pads

16 Air Admittance Valves

Est. 1350-2025 CFM

50side_thumb.jpg

2050-50-SA

ODOR CONTROL SYSTEM

Side Access

50 lb Media

1 Canister

1 Mist Eliminator Pad

2 Air Admittance Valves

Est. 60-70 CFM

image.png

2050-100-IP

ODOR CONTROL SYSTEM

Vertical or Side Access Flange

100 lb Media

2 Canisters

1 Mist Eliminator Pad

2 Air Admittance Valves

1 Float

Est. 120-150 CFM

2050-450-ipthumb.jpg

2050-450-IP

ODOR CONTROL SYSTEM

Side Access Flange

450 lb Media

9 Canisters

2 Mist Eliminator Pads

8 Air Admittance Valves

2 Inflow Preventers

Est. 650-700 CFM

2050-1400 thumb.jpg

2050-1400

ODOR CONTROL SYSTEM

Side Access Flange

1400 lb Media

28 Canisters

8 Mist Eliminator Pads

16 Air Admittance Valves

Est. 1350-2025 CFM

50ip_thumb.jpg

2050-50-IP

ODOR CONTROL SYSTEM

Vertical Access Flange

50 lb Media

1 Canister

1 Mist Eliminator Pad

2 Air Admittance Valves

1 Float

Est. 60-70 CFM

2050-200.jpg

2050-200

ODOR CONTROL SYSTEM

Side Access Flange

200 lb Media

4 Canisters

1 Mist Eliminator Pad

2 Air Admittance Valves

Est. 250-300 CFM

2050-900thumb.jpg

2050-900

ODOR CONTROL SYSTEM

Side Access Flange

900 lb Media

18 Canisters

4 Mist Eliminator Pads

8 Air Admittance Valves

Est. 900-1350 CFM

2050-100.jpg

2050-100

ODOR CONTROL SYSTEM

Vertical Access Flange

100 lb Media

2 Canisters

1 Mist Eliminator Pad

2 Air Admittance Valves

Est. 120-150 CFM

200ipthumb.jpg

2050-200-IP

ODOR CONTROL SYSTEM

Side Access Flange

200 lb Media

4 Canisters

1 Mist Eliminator Pad

2 Air Admittance Valves

Inflow Preventers

Est. 250-300 CFM

2050-1000-ipthumb.jpg

2050-1000-IP

ODOR CONTROL SYSTEM

Side Access Flange

1000 lb Media

18 Canisters

4 Mist Eliminator Pads

8 Air Admittance Valves

3 Inflow Preventers

Est. 900-1350 CFM

bottom of page